Chiller (Environmental R407C/R410A)

หมวดหมู่สินค้า: Water Chiller

21 พฤศจิกายน 2567

ผู้ชม 6 ผู้ชม

 

 

 

ENVIRONMENTAL CHILLER

 

Industrial Chiller Series

 

 

FEATURE: 

1. Environment-friendly refrigerant R407C, R134A, R410A, etc, no harm to theozone field; 

2. Cooling Capacity range from 2KW-2500KW, with various models, can fully meet the de-mands of industrial production;

3. Europeanization designed exterior with elec-trostatic spray coating, simple structure and el-egant appearance.

 

The-air-cooled-chiller

 

Working Principle

When the air cooled chiller starts, the refrigerant absorbs the heat from the cooled object in the evaporator and vaporizes. The compressor continuously extracts the generated gas from the evaporator and compresses it into high-temperature, high-pressure vapor. The refrigerant vapor is then sent to the condenser, where it undergoes heat exchange with the air. After releasing heat, it condenses into a liquid. The liquid refrigerant, after being depressurized by the expansion valve, enters the evaporator where it vaporizes again, absorbing heat from the cooled object. This heat exchange process is repeated until the industrial water is cooled to the desired temperature.

 

Working Principle

Compressor Temp. sensor
Condenser Water tank
Dry filter Pump pressure gauge
Expansion valve Pump
Evaporator By-pass valve
Ball valve Low pressure switch
Anti-freezing switch High pressure switch
Level sensor Blower

 

 

|

 

 Application Scope in the Industry

Chillers are widely used in various industrial productions such as plastics, electronics manufacturing, electroplating, pharmaceuticals, chemical engineering, ultrasonic cooling, and printing. They are employed in the cooling of molds for plastic processing machinery, significantly improving the surface smoothness of plastic products, reducing surface flaws and internal stress, preventing shrinkage and deformation, facilitating mold release, accelerating product shaping, and thus greatly enhancing the production efficiency and product quality of plastic molding machines.

 

 

 

 

Injection Molding Industry

Injection Molding Industry

Extrusion Industry

Extrusion Industry

Plastic Packaging Industry

Plastic Packaging Industry

Pharmaceutical Industry

Pharmaceutical Industry

Automotive Manufacturing Industry

Automotive Manufacturing Industry

Chemical Engineering Industry

Chemical Engineering Industry

Electroplating Industry

Electroplating Industry

Electronics Industry

Electronics Industry

Printing Industry

Printing Industry

|

 

 Highlights of the Product

Scroll Compressor

The entire range of Xiecheng air cooled chillers utilizes scroll compressors. The compressor serves as the heart of the entire refrigerant cycle system. The scroll compressor adopts a dual-flex design, ensuring tight sealing between the scroll discs. This design allows the scroll discs to separate radially and axially, allowing debris or liquid to pass through without damaging the compressor. This results in increased compressor lifespan, enhanced reliability, better liquid tolerance, and improved tolerance for impurities.Scroll Compressor


Characteristics of the compressor:



       Operating range


1. Dual-flex design: The compressor features a dual-flex design, ensuring flexibility and reliability in operation.
2. Wide range of product capacity: The compressor is available in a wide range of capacity options, catering to various cooling requirements.
3. High energy efficiency: The compressor is designed for high energy efficiency, optimizing the cooling process and reducing energy consumption.
4. Low noise and vibration levels: With advanced design and precision engineering, the compressor operates with reduced noise and vibration levels, providing a quieter and more comfortable environment.
5. One-touch startup: The compressor is equipped with a user-friendly one-touch startup feature, making operation and startup quick and convenient.

Operating range

 

|

 

 Shell and Tube Evaporator

The air cooled chiller utilizes a shell and tube evaporator. In this system, the refrigerant evaporates inside the heat exchange tubes, while water flows on the shell side. To enhance the heat exchange efficiency, a 2mm thick baffle plate is installed on the shell side, causing the water to flow back and forth to create ice brine. Additionally, to maintain a stable operating temperature, the exterior shell of the evaporator is covered with insulation material.

 

For the heat exchange tubes, we employ high-efficiency seamless copper tubes. These tubes undergo a grooving process to form internal thread fins, thereby increasing the heat exchange surface area with the refrigerant. With this technology, the heat transfer area is doubled, significantly improving the heat transfer efficiency.

 

Shell and Tube Evaporator

 

|

 

 Finned Type Condenser

By adopting a high-efficiency copper tube with aluminum finned type condenser, the air cooled chiller effectively dissipates heat. The finned structure increases the heat exchange surface area between the condenser and the surrounding environment, improving the heat dissipation efficiency. The excellent thermal conductivity of copper tubes, combined with the efficient heat dissipation characteristics of aluminum fins, ensures high efficiency during the cooling process.

 

Additionally, the application of light water aluminum and blue aluminum foils provides an additional protective layer. They help prevent corrosion of the copper tubes in corrosive environments, thereby extending the lifespan of the condenser and maintaining optimal refrigeration performance.

 

Finned Type Condenser

 

 

 

|

 

 Product Details

Microcomputer Controller

 

Microcomputer Controller

 

 

The air cooled chiller features an industry-leading LCD display microcomputer controller. This controller provides simultaneous display of the chiller's outlet temperature and the set temperature for precise temperature control. The user-friendly interface allows for easy operation and adjustment. With this controller, the water temperature can be precisely controlled within a range of 3°C to 50°C, ensuring optimal cooling performance.

 

 

 

 

 

Drying Filter System

 

Drying Filter System

 

The air cooled chiller is equipped with Emerson filters, which effectively remove impurities from the refrigerant and absorb free moisture in fluorocarbons. This system prevents the formation of ice blockages, particularly in narrow sections of pipelines (especially the valve ports of thermal expansion valves). It ensures the purity of the refrigerant and protects the compressor from potential damage.

 

 

 

Efficient Cooling System

 

Efficient Cooling System

 

 

The air-cooled chiller is equipped with a high-efficiency cooling system that includes low-noise external rotor fans. These fans are specifically designed to accelerate heat dissipation and enhance the overall cooling efficiency of the system. By improving airflow and maximizing heat transfer, this system ensures optimal cooling performance while operating with minimal noise levels.

 

 

 

 

High and Low Pressure Protection System

 

High and Low Pressure Protection System

 

The high and low pressure protection system is designed to enhance the safety and efficiency of water pump operations. It involves the installation of high and low pressure gauges as well as a pump pressure gauge to continuously monitor the pressure of the water pump during operation.

 

 

 

 

Water Pumps

 

Water Pumps

 

 

For chiller models ranging from 1 to 6HP, Orank stainless steel pump heads are used. For models with 8HP or higher, Taiwan Yuanli pipeline pumps are employed. These water pumps are known for their low noise operation, leak-free performance, and maintenance-free characteristics. They ensure reliable and efficient water circulation within the chiller system.

 

 

 

 

Electrical Self-control System

 

Electrical Self-control System

 

The electrical self-control system consists of power supply and automatic control components. It utilizes Siemens electronic components to ensure stable operation of the equipment. It incorporates a comprehensive range of safety protection devices, including current overload protection, high and low-pressure protection systems, and electronic time delay. These safety features provide robust protection and are complemented by an intuitive display system that alerts users to any abnormalities.

 

model

UNIT

XC-LF3AH

XC-LF5AH

XC-LF6AH

XC-LF8AH

XC-LF10AH

XC-LF12AH

 

Cooling capacity

Kw

8.6

14.9

17.2

23

29.4

37

 

Kcal/h

7396

12814

14792

29780

25284

31820

 

Compressor

Input power

KW

2.2

3.75

4.5

6

3.75x2

4.5x2

 

Rated power

HP

3

5

6

8

5x2

6x2

 

Power

 

3PH-380V/50HZ (220V/220V/415V/460V 50Hz/60Hz)

 

Evaporator

Types of

Shell and tube type/stainless steel plate change

 

Water pipe diameter

lnch

1"

1"

1"

2''

2''

2''

 

Frozen media

Types of

R22(R407C/R134A)

 

way to control

Capillary

(Capillary tube) Externally balanced thermal expansion valve

 

Frozen water

M³/h

1.36

2.2

2.6

3.5

4.3

5.03

 

Air-cooled condenser

Types of

High efficiency copper tube sleeve aluminum fin type + low noise outer rotor fan

 

Fan power

W

180x1

180x2

180x2

420x2

420x2

420x2

 

Water pump

power

Kw

0.37

0.75

0.75

1.5

1.5

1.5

 

HP

0.5

1

1

2

2

2

 

Lift

m

15

25

25

15

15

15

 

flow

l/min

75

110

110

360

360

360

 

heating equipment

Types of

Heating pipe

 

power

KW

6

9

9

12

12

18

 

safety protection

Compressor overheat protection, overcurrent protection, high and low pressure protection, over temperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection

 
 

Dimensions (L*W*H)

mm

960*630*1025

1280*680*1225

1280*680*1225

1550*830*1508

1550*830*1508

1550*830*1508

 

 

 

 

Model UNIT XC-LF1A-R7 XC-LF2A-R7 XC-LF3A-R7 XC-LF5A-R7 XC-LF6A-R7 XC-LF8A-R7 XC-LF10A-R7 XC-LF12A-R7 XC-LF15A-R7 XC-LF20A-R7 XC-LF25A-R7 XC-LF30A-R7 XC-LF40A-R7 XC-LF50A-R7
XC-LF1A-R0 XC-LF2A-R0 XC-LF3A-R0 XC-LF5A-R0 XC-LF6A-R0 XC-LF8A-R0 XC-LF10A-R0 XC-LF12A-R0 XC-LF15A-R0 XC-LF20A-R0 XC-LF25A-R0 XC-LF30A-R0 XC-LF40A-R0 XC-LF50A-R0
Cooling Capacity Kw 3.42 6.2 8.6 14.9 17.2 23 29.4 37 46.5 62 74.1 92.7 122.3 147.3
Kcal/h 2941.2 5332 7396 12814 14792 19780 25284 31820 39990 53320 63726 79722 105178 126678
Compressor Input Power Kw 0.75 1.5 2.2 3.75 4.5×2 6 3.75x2 4.5x2 3.75x3 7.5x2 9x2 11x2 15x2 18.8x2
Rated Power Hp 1 2 3 5 6 4×2 5×2 6×2 5×3 10×2 12.5×2 15×2 20×2 25×2
Power   1PH-220V/50HZ 3PH-380V/50HZ (220V/220V/415V/460V 50Hz/60Hz)
Evaporator Type Water Tank with Coil(Shell and Tube)
Pipe Diameter lnch 1'' 1'' 1'' 1'' 1'' 2'' 2'' 2'' 2.5‘’ 2.5‘’ 3‘’ 3‘’ 4‘’ 4‘’
Refrigerant Type R407C(R410A)
Control Method   Capilary Tube (Capillary) Externally balanced thermal expansion valve (Capilliary) Expansion Valve
Cooling water flow M³/h 0.476 0.908 1.36 2.22 2.6 3.95 4.42 5.03 7.1 8.84 10.06 13.6 17.75 21.9
Condenser Type High-efficiency copper tube sleeve aluminum fin type + low noise outer rotor fan Finned Copper Tube + Low Noise Outer Rotor Fan
Fan Power W 90x1 170x1 180x1 180x2 180x2 420x2 420x2 420x2 800x2 420x3 800x3 800x3 420x6 800x6
Water Tank Capacity Liter 20 25 40 45 45 80 80 80 100 150 210 210 380 420
Pump Power Kw 0.37 0.37 0.37 0.37 0.75 1.5 1.5 1.5 2.2 2.2 4 4 5.5 7.5
hp 0.5 0.5 0.5 1 1 2 2 2 3 3 5 5 7.5 10
Distance m 15 15 15 25 25 15 15 15 16 16 16 16 16 18
Flow Rate l/min 75 75 75 110 110 360 360 360 360 360 700 700 700 800
Safety Protection Compressor overheat protection, overcurrent protection, high and low pressure protection, overtemperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection High and Low Pressure Protection, Overload Protection, Overtemperature Protection, Phase Sequence Protection, etc.